Testing Purposes
According to MIL-I-17563C requirements of U.S. MIL standards, various durability testings are applied to infusion UC168. The results show that infusion UC168 meets the requirements of MIL-I-17563C.
Durability Testing Items:
1. Heat resistance:200°C × 200hrs
2. Oil resistance:150°C × 200hrs
3. Refrigerant resistance:150°C × 200hrs
4. Gasoline resistance:temperature × 120hrs
5. Cyclical hot / cold resistance:150°C × 1hr→cooling→-76°C × 2min→30 dollars back
Evaluation (The following were measured at room temperature):
1. Pressure resistance after testing: 6.0kg/cm2 (MIL-I-17563C requirements is 5.6 kg/cm2)
2. The weight change after testing
3. Infusion:Infusion UC168
4. Color:Colorless and Transparent - Light Yellow
5. Principal Ingredients:Multifunctional Methacrylate Polymer Resin
6. Ratio:1.07
7. Viscosity:10cps
8. Refractive Index:1.450
9. PH : 6.2
10. Boiling Point:87°C/5mmHg,205°C/760mmHg
11. Melting Point:-12°C
12. Flash Point:107°C
13. Water-Soluble Characteristics:Completely Soluble
14. Water Reactive:None
15. Odor:weak fat flavor